Together, EIA and JESDA detail the ESD requirements from the earliest steps in the assembly process to the final packing, shipping, and handling of. JEDEC. STANDARD. Requirements for Handling Electrostatic-Discharge- Sensitive (ESDS) Devices JESDA (Revision of EIA). DECEMBER charging up to dangerous levels (> 1kV) (JEDEC specification JESDA). Verify that machines and microscopes are properly grounded per JESDA.

Author: JoJozshura Vudokinos
Country: Qatar
Language: English (Spanish)
Genre: Literature
Published (Last): 23 July 2014
Pages: 326
PDF File Size: 6.16 Mb
ePub File Size: 4.32 Mb
ISBN: 123-5-40463-232-4
Downloads: 84840
Price: Free* [*Free Regsitration Required]
Uploader: Shakar

A resistor in the grounding wire is optional. However a lower value may be used if local safety requirements can still be met. NOTE — Surface resistance is expressed in ohms.

Its value shall be within the limits specified in table 2, 1. A jsed625 having a surface resistivity of at least 1 x ohms per square or volume resistivity of at least 1 x ohm centimeter. A packaging system that provides electrostatic protection and limits triboelectric charging to levels that do not result in device damage. A barrier or enclosure that limits the penetration of an electrostatic field so jsed625 its jjesd625 do not reach the stored or contained devices and produce damage.

The dc voltage divided by the current passing between two electrodes of specified configuration that contact the same side of a insulative jese625 or item. When R2 or R3 are used, the resistor values shall be as recommended by the ESD protective equipment jesr625.

The lowest level of ESD that produces changes in device characteristics such that the device fails to meet its specified characteristics. NOTE — Topically treated tubes, trays, magazines and carriers tend to lose their static protective properties with use and should be evaluated periodically for acceptable performance. Where both grounds are used, they shall be connected bonded together. The entire low-impedance path from a piece of electrical equipment to a hardground electrode e.

When the supplier’s original packing materials and containers are noncompliant to this standard, the ESDS devices shall be rejected and returned in the original materials and containers. The passage of a static charge through an electrostatic-discharge-sensitive ESDS device can result in catastrophic failure or performance degradation of the part.

  DANFOSS EKC 201 PDF

Otherwise, the attribute fail must be recorded. An example of an ESD protected package caution label is shown in figure 2.

REQUIREMENTS FOR HANDLING ELECTROSTATIC-DISCHARGE-SENSITIVE (ESDS) DEVICES

All ESDS devices shall be removed from the worksurface while making these measurements. A source of charged air molecules ions. The required and recommended ESD item checks are listed in table 2. A table top or other surface on which to work that has a resistance to ground of less than ohms ground: Records shall be maintained for at least two 2 complete years. The generation of electrostatic charges when two pieces of material in intimate contact are separated where one or both is an insulator.

JESDA ESD Handling Dec, _图文_百度文库

When both equipment and earth grounds are used at the same ESD protective workstation they shall be bonded together at some point in the ground system. Applying or removing static generating tapes and labels to antistatic tubes, magazines and carriers shall not be done with Jssd625 devices inside. Referring to the property of material that inhibits triboelectric charging.

Wire splices should jesd6255 crimped or soldered. The wire should be attached to physical structures to prevent mechanical damage. The transfer of electrostatic charge between bodies or surfaces that are at different electrostatic potentials. The intent of this document is for users to incorporate these minimal requirements into their ESD control program to provide a consistent ESD protection level for their products. A short form of electrostatic. NOTE — Substantial generation of static electricity can be caused by contact and separation of two materials or by rubbing two substances together.

As a minimum, the records shall show dates of training, length of training session, topics covered, and the name of the trainer.

NOTE — The electrical charge is due to the transfer of electrons within a body polarization or from one body to another. This document is copyrighted by the Electronic Industries Alliance and may not be reproduced without permission. ESD Protective Smocks 6. Recommended Weekly a ESD protected workstation.

  CLASSICAL BAGUAZHANG PDF

Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. Adding a Data Visualiz NOTE 1 Volume resistivity is generally expressed in ohm centimeters. Electrical charge at rest. Where the choice of color is arbitrary, it is suggested that the symbol be black on a yellow background.

During application of any antistatic chemical, the user must consider the following: A designated connection, location, or assembly used on an ESD protective material or device that is intended to accommodate electrical connection from the device to ESD ground. By downloading this file the individual agrees not to charge or resell the resulting material. Monochromatic reproduction in any color that contrasts with the background may be used.

The ionizer shall be aimed at the devices and operator’s hands rather than at the operator. When ESD protective smocks are worn, they shall cover all personal garments above the waist except at the neck area. NOTE — A material’s antistatic property is not necessarily correlatable with its resistivity or resistance.

Air velocity measurements are not required. Grounded flooring or floor mats are only required when personnel or mobile ESD protective workstations utilize floor grounding methods.

A typical grounding system for an ESD protected workstation is illustrated in figure 1. The requirements within this standard were derived from existing industry standards, specifications, test methods, and input from various industry reviews.

The caution label shall be legible to normal vision at a distance of three feet. Static Generating Sources and Charged Surfaces 5. No claims to be in conformance with this standard may be made unless all requirements stated in the standard are met.